Installation instructions • Read online or download PDF • Rockwell Automation IF8 Compact IF8 Analog Input Module User Manual. Rockwell Automation IF8 Compact IF8 Analog Input Module User Manual – Download. Rockwell Automation IF8 Compact IF8 Analog. The Compact I/O modules can be used with a CompactLogix controller, IF4FXOF2F. IF8. IF16C. IF16V. IR6. IT6.

Author: Mizragore Kashicage
Country: Algeria
Language: English (Spanish)
Genre: Career
Published (Last): 4 April 2013
Pages: 117
PDF File Size: 17.98 Mb
ePub File Size: 3.41 Mb
ISBN: 237-8-58605-867-7
Downloads: 29789
Price: Free* [*Free Regsitration Required]
Uploader: Mishakar

In that case, graphical screens are provided by the programmer to simplify configuration. You can use the bare wire or a spade lug. Rockwell Automation Support Rockwell Automation janual technical information on the web to assist you in using our products.

Rockwell Automation IF8 Compact IF8 Analog Input Module : Owner’s manual

The latches will momentarily open and lock into place. Replacing a Single Modu le within a System Tell us what’s missing. Mounting screws are required on every module. Remove the label from the door, mark manuall identification of each terminal with permanent ink, and slide the label back into the door. Use a power supply that matches the input transmitter manuaal. The terminals will accept a 6.

  HANDBOEK VERANDERMANAGEMENT PDF

To allow communication between the controller and module, move the bus lever fully to the left 4 until it clicks.

Loosen the terminal screws to be wired. Tell us about it. Overall hole spacing tolerance: Approximate Shipping Weight with carton g 0.

Rockwell Automation

For More Manuak ation Your manual failed to upload Host Controller Spacing for single-wide modules 35 mm 1. Your markings ID tag will be visible when the module door is closed.

Wire fragments that fall into a module could cause damage at power up. However, some systems, like the ADN DeviceNet Adapter, also allow the bits to be altered as part of the control program, using communication rungs. Don’t see a manual you are looking for?

NC Wiring for channels are identical. Channel 0 and 1 Configuration Data Channel 0 and 1 configuration data is shown below. Or point us to the URL where the manual is located. Lock the end cap bus terminator 6.

  ESBE VTC511 PDF

Scripting must be enabled to use this site.

Use M4 or 8 panhead screws. Route the wire under the terminal pressure plate.

Attach an end cap terminator 5 to the last module in the system by using the tongue-and-groove slots as before. Input Data File Word For each input module, slot x, words in the input data file contain the analog values of the inputs. Ensure it is locked firmly in place. The same information applies to 1769-kf8 channels.

Locate holes every This lets you individually cancel each low process alarm latch.

The terminal screws are non-captive.