AAMA 501.1 PDF

AAMA 501.1 PDF

Buy AAMA STANDARD TEST METHOD FOR WATER PENETRATION OF WINDOWS, CURTAIN WALLS AND DOORS USING DYNAMIC. The American Architectural Manufacturers Association (AAMA) recently AAMA , the Standard Test Method for Water Penetration of. *Standard Test Method for Water Penetration of Windows, Curtain Walls and Doors Using Dynamic Pressure. Establishes the equipment, procedures and.

Author: Felkis Shakashicage
Country: Armenia
Language: English (Spanish)
Genre: Music
Published (Last): 1 September 2010
Pages: 96
PDF File Size: 17.13 Mb
ePub File Size: 17.40 Mb
ISBN: 214-7-29380-238-9
Downloads: 33011
Price: Free* [*Free Regsitration Required]
Uploader: Barisar

Lab personnel attach an impressive array of dial indicators on various parts of the specimen, then chamber pressure is cranked up.

AAMA – AAMA Releases Updated Standard Test Method for Water Penetration Using Dynamic Pressure

The authors look forward to other investigators improvements to our methods; and help to aaka ASTM to consider developing a new standard for its use. Air tests can be harbingers of results to come, so we participants tend to hold our breaths awaiting the outcome.

Top 10 Fixesviews 39 comments My Windows Leak! Top 10 Installer Screw-ups Part 2 9, views 9 comments. Yes, glass does indeed bend, Virginia, but it also breaks. Locating the sources of water leakage in existing building facades is challenging, time-consuming, and an ongoing annoyance to building owners. Now about the tests… A typical test sequence for a prominent aamw in Chicago would list as follows:.

This article, originally written in is being reprinted here in very fond awma of my friend A. During testing, the interior face of the test area is inspected for water leakage. Repair or replace windows. Upon the completion of a successful 5011.1, the product meets the performance criteria for air infiltration resistance and water penetration resistance or does not meet criteria and further remediation may be required to pass.

AAMA Pubstore Product Listings –

PPVs eliminate the need for interior test chambers, reduce setup costs, and allow for the testing of walls where conventional test chambers cannot be practically constructed. Assurance Testing Inspection Certification.

  ENID BLYTON THE MYSTERY OF THE BURNT COTTAGE PDF

Construction Research Lab Announcement.

The first step in an air infiltration test is to mask off 501.11 “specimen” – that’s the assembly you intend to test – and measure the airflow through the chamber. STP Reprints and Permissions. Fenestration products are only included in testing if they are installed as a component of the exterior wall test specimen.

It has been cut, moved, welded, cut, drilled, sealed, cut apart, craned and bolted. About windows amp glass.

Whether your business is local or global, we can ensure your products meet quality, health, environmental, safety, and social accountability standards for virtually any market around the world. Usually the manufacturer forgets to send something, and invariably it is the very first thing you need to install. The lab removes air from the chamber to achieve test pressure while dousing the mockup with hundreds of gallons of water delivered by large spray racks.

Stay on Page Continue to Compass. Validating the specifications, value and safety of your raw materials, products and assets. Looking closer, however, you notice that the steel has an odd appearance. Some pieces are old, some new. Rainscreens and Weather Barriers Why did my glass break? Is It Really Safe? A spray rack is used to apply hurricane-volumes of water to the test specimen while blowers are used to create a negative pressure on the inside.

The test runs for 15 very long minutes. The indicators record the amount of deflection bending which occurs. The ease of set up, flexibility, and the capability to control the start and stop of the leaks, makes this testing procedure a valuable tool for the forensic leak investigator. This test is utilized to provide quality assurance for evaluating the structural adequacy of exterior wall systems and their ability to resist aqma penetration and air leakage. If the specimen sucks in uncontrolled water, the test is a fail, and that sucks 051.1 the testing cannot proceed until the leak is diagnosed and fixed.

  EUROCENTRISM AMIN PDF

Any permanent bending or breakage would constitute a failure.

He was about 85 years old. It has seen searing Florida sun, torrential rainfalls, and uncountable performance tests. Photo of the day.

AAMA 501.1-17

Testing continues for 15 minutes. The vintage steel has been used, reused, and used again. Ultimate Quality Control Mockup Testing: Dynamic water penetration testing is conducted at the specified air pressure differential by utilizing a wind generator employing an 84″ diameter propeller. Mark Meshulam is a construction consultant, glass consultant and expert witness located in Chicago, IL, USA This article, originally written in is being reprinted here in very fond memory of my friend A.

Global Reach Intertek is the industry leader with over 42, people in 1, locations in over countries. Uniform Load Deflection These are just a few of the many gauges used to measure deflection of every part of the specimen while it is being subjected to wind loads far greater than anything the building will see in its future service life. Same spray rack, also 15 minutes. Witnesses such as myself are inside the chamber with flashlights and scuba tanks kidding looking for leaks.

Drowning during this test is infrequent, however heat exhaustion is a distinct possibility because the chamber air conditioner often fights a losing battle against a baking Miami sun. Through our network of over 43, people in 1, laboratories and offices in countries, Intertek provides quality and safety solutions to a wide range of industries around the world.

In this test, lab personnel pump air from the chamber with a blower while measuring the amount of air being removed while maintaining test pressure, often 6.