AS/NZS Specifies the construction, dimension and test requirements for single-core and multi-core polymeric insulated and non-metallic sheathed. AS/NZS (R). Electric cables – Polymeric insulated – For working voltages up to and including / V. standard by. AS/NZS Category: Cord and Cables. Description: Electric cables – Polymeric insulated – For working voltages up to and including / V.

Author: Fenrishura Shaktizilkree
Country: Brazil
Language: English (Spanish)
Genre: Environment
Published (Last): 12 February 2010
Pages: 278
PDF File Size: 20.15 Mb
ePub File Size: 1.28 Mb
ISBN: 206-4-42889-201-6
Downloads: 34047
Price: Free* [*Free Regsitration Required]
Uploader: Fegal

These are the two measurements that compliance is confirmed and is required by nearly all cable standards today. See examples in Figure 1 for various types of extrusions. This document defines the principles upon which electrical installations must be designed and installed in order to protect people, livestock and property from the risk of electrical shock, fire and physical injury hazards. It only needs to meet the specified resistance value. The nzzs dot points will be addressed in part 2.

Keep up to date with latest from this campaign through our Facebook page!

PE has significantly greater dielectric strength compared to PVC, which is a blend of a number of ingredients of which Poly Vinyl Chloride is one. The manner in which compliance of these materials is confirmed is complex and will be covered in some detail qs the discussion later on 50000.2 materials. The following sections refer to a range of tests that are conducted on cables to ensure compliance.

Due to the level of detail required to zs this topic it will be presented in two parts. Take the online training and add your voice to this campaign!. In the first part of this article I will address the first dot point only. And neither is the diameter of a conductor important as far as compliance is concerned. Ns the case of insulation thickness, this varies with material type and conductor size.

As previously explained it is common for low voltage cable standards to define an insulation thickness which varies for different conductor sizes, with the largest conductor having the thickest insulation and sheath.

This is a legally mandated document, and therefore the risk of non-compliance is not only unsafe it is also illegal. The following briefly describes each 5000.2 the above tests, their purpose and how they relate to the mechanical performance of the cable in terms of installation and long term operation of the cable.

  BUDDHA ULAZI U BAR PDF

In terms of cables the wiring rules nss direct reference to Australian and New Zealand Standards as the principle means to ensure that its scope is fulfilled.

They may soften, but will not flow. It will be fairly obvious that the thickness of the insulation and sheath material must be aligned with the typical use of the product.

上海南大集团有限公司 — Products — AS/NZS standard for Australia & New Zealand Market

The insulation thickness for LV cables is not primarily based on electrical requirements, but more on mechanical considerations. Cross-Linked materials are more thermally stable compared to Thermoplastic materials and will not flow when subjected to high operating temperatures. Introduction In this article I will try to unravel some of the less known aspects of cable compliance with the overall aim to give the user the correct information to make 500.2 informed decision when selecting cable products.

To be continued in Part 2. The insulation thickness on large conductor sizes is greatest due to the nsz risk of mechanical damage during handling of large and heavy cables. What may be not so obvious is how the thickness is actually measured. A 35mm2 copper conductor, for example, does not need to have 35mm2 of copper in it. Ability to Carry Rated Current The ability of an electrical cable to carry its design electric current is largely dependent on the electrical resistance of the conductor.

AS/NZS 5000.2

The peak Australian electrical industry body, the National Electrical and Communications Association NECA and the world’s leading electrical industry information portal Voltimum have joined forces in an effort to raise awareness and educate users of the dangers of using product that is not compliant to Australian Standards.

The thickness of insulation and sheath of cables is done by taking six measurements at the location where the material is thinnest using optical magnification equipment of at least 10X to allow a reading of 0. Modern manufacturing techniques have seen the introduction of automated electronic measurement systems to replace manual methods that provide a significant improvement in repeat accuracy. A variety of cable insulating materials exists in the cable manufacturing industry, all having differing properties, but all having the primary attribute of being suitable as an electrical insulating material.

The standards referred to in details the test method xs to conduct each test. Their differences lie in their cost, processability, dielectric performance, mechanical strength and flexibility to name a ss.

  EL EXITO NO ES CASUALIDAD TOMMY NEWBERRY PDF

Type tests need not be repeated unless changes are made in the cable materials or design or manufacturing process. The measurement method described above has traditionally been carried out by manual methods and is therefore subject to human error. Privacy Policy Terms of Service. Subscribe to receive the lastest news from the electrical industry brought to you by Voltimum. Smaller diameter conductors, such as compacted, or the larger diameter non-compacted conductors, do not matter.

Does it Comply?

There has been much publicity recently about the recall of non-compliant building cables, but what does compliance actually mean as far as a cable is concerned and how does it actually relate to performance? Join the fight against non-compliant products! The improved electrical properties of XLPE is a result of the chemical makeup of the material, being almost exclusively polyethylene.

Type of Business Contractor emp. Some of the common cable insulating materials are listed below:.

To confirm that a cable can hold its rated voltage the cable is subjected to the following checks and test:. These performance requirements are largely based on the mechanical properties of the materials used in cables. This first part looks at the electrical and physical dimensional testing requirements for cables, whilst the second part looks at the range of material tests that cable materials must meet to enable compliance to be obtained.

This is a common testing principle where the test object is subjected to a higher 5000. than it would normally be expected to operate at, with the intention to flush 5000.2 extrusion defects or weaknesses in the insulation materials. Only the electrical resistance is mandatory. The actual area is not critical nor is it a bzs that must be measured.

This is a 5000.2 important and often misunderstood issue. When looking at the impact of non-compliant resistance on the current rating of a cable, its impact is relatively small, as its current rating is proportional to the inverse of the square root of resistance.

Then there is the material that is in contact with the conductor. Voltage tests nnzs on cables are done at higher than normal operating levels.